MR Wrist W/WO Protocol
Revised - 2/22/19
- Charge as Wrist WWO
- 3T Scanner Only
- Wrist/ Flex Coil
- Always Scan Individually
- If hardware is present:
- Do STIR instead of fat-sat mid-TE
- Do non-fat-sat T1 post-contrast
Plane | Weighting | Mode | Slice | Gap | FAT SAT | FOV | Scan Range |
---|---|---|---|---|---|---|---|
AXIAL | T1 | TSE | 2-3mm | 0.5mm | None | 12cm | 3cm Above/Below Wrist |
AXIAL | Mid TE T2 Fat Sat | TSE | 2-3mm | 0.5mm | SPAIR | 12cm | 3cm Above/Below Wrist |
COR | T1 | TSE | 2-3mm | 0.5mm | None | 12cm | Angle Relative to Radio-Ulnar Joint |
COR | Mid TE T2 Fat Sat | TSE | 2-3mm | 0.5mm | SPAIR | 12cm | Angle Relative to Radio-Ulnar Joint |
SAG | Mid TE T2 Fat Sat | TSE | 2-3mm | 0.5mm | SPAIR | 12cm | Angle Relative to Radio-Ulnar Joint |
SAG PRE(if giving gad for infection/osteo) | T1 | TSE | 2-3mm | 0.5mm | None | 12cm | Angle Relative to Radio-Ulnar Joint |
POST CONTRAST | |||||||
AXIAL | T1 Fat Sat | TSE | 2-3mm | 0.5mm | SPIR | 12cm | Same as pre |
COR | T1 Fat Sat | TSE | 2-3mm | 0.5mm | SPIR | 12cm | Same as pre |
SAG (optional) | T1 Fat Sat | TSE | 2-3mm | 0.5mm | SPIR | 12cm | Same as pre |