MR ED Infection Screening Total Spine W

Scan Notes

Last updated: 1/31/2024
Charge as: Total Spine W
Scanner preference: None 

Indication:
This abbreviated total spine MRI is to be used for the purpose of ruling-out infection in the spine. 

Optional Axial T2 and Optional Axial +T1 coverage:
​​​​​​​These axial sequences should only be performed through the level(s) of potential infection as seen on sagittal images, at the technologist’s discretion. If unsure, call radiologist for guidance.

Plane Weighting Mode Slice (mm) Gap (mm) FAT SAT FOV (cm) MPR Notes
HAND INJECT CONTRAST.
UPPER STATION
SAG (post gad) T2 2D TSE 3 0.3 Dixon: InPhase & Water only no
SAG (post gad) T1 2D TSE 3 0.3 Dixon: InPhase & Water only no
LOWER STATION
SAG (post gad) T1 2D TSE 3 0.3 Dixon: InPhase & Water only no
SAG (post gad) T2 2D TSE 3 0.3 Dixon: InPhase & Water only no
Optional (see note)
AXIAL (post gad) T1 VIBE/THRIVE 3 0 YES 15 no Optional. See note above.
AXIAL (post gad) T2 2D TSE 3 0.3 no 15 no Optional. See note above.