MR Pediatric Chest/Abdomen/Pelvis WO or WWO Protocol
Notes
Updated: 1/13/2022
Scanner Preference:1.5T or 3T
Coil: Torso or Cardiac
Coil: Torso or Cardiac
Notes from the Radiologist:
- Power injections are preferred whenever possible.
- Images should be checked pre-gad for sedated patients or anytime the technologist has a question/concern. For unsedated exams, no check is required.
- For larger patients, slice thickness may be increased up to 5mm.
Plane | Weighting | Mode | Slice | Gap | FS | FOV | Notes |
---|---|---|---|---|---|---|---|
AXIAL | T2 | TSE MV MS | 3.5mm | 1mm | SPAIR | Fit to Patient | Entire chest, abdomen, and pelvis, skin to skin |
COR | STIR | TSE MV MS | 3.5mm | 1mm | STIR | Fit to Patient | Entire chest, abdomen, and pelvis, skin to skin |
COR | DWIBS | IR EPI SS | 5mm | 1mm | None | Fit to Patient | Entire chest, abdomen, and pelvis, skin to skin |
SAG | STIR | TSE MV MS | 3.5mm | 1mm | STIR | Fit to Patient | Spine only (make routine, previously this was an optional sequence) |
COR | T1 | mDIXON | 3.5mm | 1mm | DIXON | Fit to Patient | Entire chest, skin to skin, turn ON in/out-of-phase |
Inject Contrast | Power injection preferred | ||||||
COR | T1 | mDIXON | 3.5mm | 1mm | DIXON | Fit to patient | Dynamic acquisition: 30 sec, 60 sec, 90 sec; turn OFF in/out-of-phase |
AXIAL | T1 | mDIXON | 3.5mm | 1mm | DIXON | Fit to patient | Chest, abdomen, pelvis. |