MR Pediatric MRI/MRV Le Klippel - Trenaunay WWO Protocol
Notes
Last updated: 1/13/2022
Scanner preference: 1.5T or 3T
Coil: Torso
Notes from the Radiologist:
- Scanned as bilateral lower extremities W/WO
- Images should be checked pre-gad for sedated patients or anytime the technologist has a question/concern. For unsedated exams, no check is required.
Plane | Weighting | Mode | Slice | Gap | FS | FOV | Notes |
---|---|---|---|---|---|---|---|
AXIAL | T2 | TSE MV MS | 3.5mm | 1mm | SPAIR | Fit to Patient | Iliac crests through ankles |
COR | STIR | TSE MV MS | 3.5mm | 1mm | STIR | Fit to Patient | Iliac crests through ankles |
COR | T1 | mDIXON | 3.5mm | 1mm | DIXON | Fit to Patient | Turn ON in/out-of-phase |
Inject Contrast | |||||||
AXIAL | T1 | mDIXON | 3.5mm | 1mm | DIXON | Fit to patient | Iliac crests through ankles |
COR | T1 | TSE MV MS | 3.5mm | 1mm | SPIR | Fit to Patient | Iliac crests through ankles |